Gas turbine unit BKGPEA-200.
Heat recovery system (HRS) gas turbine unit.
Recuperator of gas turbine unit used for premises heating
Result
During operation extra efficiency have been achieved
ЭPERFORMANCE PARAMETERS:
HOT SIDE
COLD SIDE
Inlet temperature, °С
550
-20
Outlet temperature, °С
160
40
Flow rate, Nm3 / h
800
5 700
Pressure drop in channels, mm. WG
14
44
Thermal power, kW
122