Recuperators for waste recycling

Sewage treatment plant
Sewage treatment plant

Replacing a failed heat exchanger while retaining binding dimensions.

Finished
4th quarter 2017

PERFORMANCE PARAMETERS:

HOT SIDE

COLD SIDE

Inlet temperature, °С
300
50

Outlet temperature, °С
165
214

Flow rate, Nm3 / h
30 000
25 000

Pressure drop in channels, mm. WG
13
92

Thermal power, kW
1 628

Waste incineration plant
Technical waste incineration unit.

Heat exchanger for flue gas utilization before gas cleaning.

New construction.

Result
All declared performance parameters were achieved.

PERFORMANCE PARAMETERS:

HOT SIDE

COLD SIDE (WATER)

Inlet temperature, °С
800
15

Outlet temperature, °С
504
94

Flow rate, Nm3 / h
7 000
12

Thermal power, kW
780

Waste incineration plant.
Technical waste incineration unit.

Recuperator for preheating combustion air.

New construction.

Accepted for implementation.

PERFORMANCE PARAMETERS:

HOT SIDE

COLD SIDE

Inlet temperature, °С
1 150
0

Outlet temperature, °С
300
247

Flow rate, Nm3 / h
40 000
200 000

Thermal power, kW
18 010

Landfill technical waste recycling.
Pesticide waste incineration plant.

Heat exchanger for cooling the ash discharged from the pesticide waste incinerator.

New construction.

Accepted for implementation.

PERFORMANCE PARAMETERS:

HOT SIDE

COLD SIDE

Inlet temperature, °С
800
20

Outlet temperature, °С
150
266

Flow rate, Nm3 / h
0,1
446

Pressure drop in channels, mm. WG
11 346

Thermal power, kW
40