Сombined heat and power plant of a steam blowing station

ТЭЦ ПВС
Thermal power plant. Steam boiler room

TGM-151 / B boiler

The project of replacing rotary air preheaters (APH) with OPT recuperators to increase the temperature of the air supplied to the burners of the boiler.

Approved in the framework of the investment program for 2018

PERFORMANCE PARAMETERS:

HOT SIDE

COLD SIDE

Inlet temperature, °С
371
30

Outlet temperature, °С
201
300

Flow rate, Nm3 / h
258 993
174 689

Pressure drop in channels, mm. WG
98
78

Thermal power, kW
17 287

Thermal efficiency, %
79,3